Attention to Internet Explorer users: ROHM website does not recommend browsing in IE 11. Please use latest browser to ensure the best performance on ROHM website.
Regarding the thermal resistance of Transistors, is it ok to consider the thermal resistance between the channels and air the same as the package thermal resistance?
There should be no major differences, similar to small-signal products. However, with power products the thermal resistance may vary depending on rating, even with the same package type.