Attention to Internet Explorer users: ROHM website does not recommend browsing in IE 11. Please use latest browser to ensure the best performance on ROHM website.
Product variations and temperature characteristics are factors, but in the case of a linear regulator with foldback type overcurrent protection, if the contact resistance when the output is shorted to ground is large, the output voltage will rise due to the product of the short-circuit current and contact resistance, resulting in a current larger than the current during a complete short-circuit.Related Link:Technical Document