Attention to Internet Explorer users: ROHM website does not recommend browsing in IE 11. Please use latest browser to ensure the best performance on ROHM website.
If ΔIL is set to 30 to 40% of the output current, a balance can be achieved between power supply performance parameters such as efficiency, load transient response, and stability.