Attention to Internet Explorer users: ROHM website does not recommend browsing in IE 11. Please use latest browser to ensure the best performance on ROHM website.
There is no diode between the input and output. Discharging the output capacitor is performed by turning ON the output transistor when the reset output becomes 'L' due to power supply drop. IOL listed in the datasheet becomes the discharge current capacity.