Attention to Internet Explorer users: ROHM website does not recommend browsing in IE 11. Please use latest browser to ensure the best performance on ROHM website.
What is the recovery method for high-side and low-side switch ICs equipped with an overcurrent limiting circuit latch after current limit is applied and the latch is OFF?
One recovery method involves turning OFF the EN (CTRL) pin and then turning it ON again or turning the power supply OFF then ON, or going below VTUVL(VUVLOL) then above VTUVH(VUVLOH).