When attaching a capacitor to the A/D input pin to increase A/D conversion accuracy, is there a concern that an excessive capacity (charging time constant) may cause deviation in voltage?
Since it takes a long time to charge the capacitor, insufficient sampling time may cause A/D conversion to start in the insufficiently charged state. A/D conversion needs to be performed after increasing the sampling time and stabilizing the voltage.