Attention to Internet Explorer users: ROHM website does not recommend browsing in IE 11. Please use latest browser to ensure the best performance on ROHM website.
Does the value of the capacitor in the bootstrap circuit of a synchronous rectifying DC/DC converter with a high/low-side Nch MOSFET configuration affect MaxDuty?
In general, MaxDuty does not include parameters of the bootstrap capacitor, but if the capacitance value is too large, there may be an influence. The value recommended on the data sheet should be used for the capacitor of the bootstrap circuit.