Attention to Internet Explorer users: ROHM website does not recommend browsing in IE 11. Please use latest browser to ensure the best performance on ROHM website.
The high side Nch MOSFET requires a bootstrap circuit for on operation, and in order to charge the step-up capacitor of this circuit with electric charge, the low side MOSFET must always be on with the switching pin in the "L" state. Because this interval (time period) is necessary, a limit on MaxDuty occurs, and it can never be 100%.