Attention to Internet Explorer users: ROHM website does not recommend browsing in IE 11. Please use latest browser to ensure the best performance on ROHM website.
The L of the RX matching circuit and the L of the VCO tank circuit might be placed parallel or close. Extend the distance and layout the Ls at right angles to one another.